← Back to CVE List
CVE-2025-52586NVD
Vulnerability Summary
The MOD3 command traffic between the monitoring application and the
inverter is transmitted in plaintext without encryption or obfuscation.
This vulnerability may allow an attacker with access to a local network
to intercept, manipulate, replay, or forge critical data, including
read/write operations for voltage, current, and power configuration,
operational status, alarms, telemetry, system reset, or inverter control
commands, potentially disrupting power generation or reconfiguring
inverter settings.
inverter is transmitted in plaintext without encryption or obfuscation.
This vulnerability may allow an attacker with access to a local network
to intercept, manipulate, replay, or forge critical data, including
read/write operations for voltage, current, and power configuration,
operational status, alarms, telemetry, system reset, or inverter control
commands, potentially disrupting power generation or reconfiguring
inverter settings.
CVSS v4.0 Base Metrics — Score 7.5 (HIGH)
Attack VectorLocal
Attack ComplexityLow
Attack RequirementsPresent
Privileges RequiredNone
User InteractionNone
Confidentiality (Vulnerable System)High
Integrity (Vulnerable System)High
Availability (Vulnerable System)Low
Confidentiality (Subsequent System)None
Integrity (Subsequent System)None
Availability (Subsequent System)None
CVSS v3.1 Base Metrics — Score 6.9 (MEDIUM)
Attack VectorLocal
Attack ComplexityHigh
Privileges RequiredNone
User InteractionNone
ScopeUnchanged
ConfidentialityHigh
IntegrityHigh
AvailabilityLow
Affected & Patched Versions
Not provided by NVD for this CVE.
Not provided by NVD for this CVE.