CVE-2025-54469OS Command Injection
NVDCVSS scored by meissner@suse.de
Vulnerability Summary
A vulnerability was identified in NeuVector, where the enforcer used environment variables CLUSTER_RPC_PORT and CLUSTER_LAN_PORT to generate a command to be executed via popen, without first sanitising their values.
The entry process of the enforcer container is the monitor
process. When the enforcer container stops, the monitor process checks
whether the consul subprocess has exited. To perform this check, the
monitor process uses the popen function to execute a shell command that determines whether the ports used by the consul subprocess are still active.
The values of environment variables CLUSTER_RPC_PORT and CLUSTER_LAN_PORT
are used directly to compose shell commands via popen without
validation or sanitization. This behavior could allow a malicious user
to inject malicious commands through these variables within the enforcer
container.
The entry process of the enforcer container is the monitor
process. When the enforcer container stops, the monitor process checks
whether the consul subprocess has exited. To perform this check, the
monitor process uses the popen function to execute a shell command that determines whether the ports used by the consul subprocess are still active.
The values of environment variables CLUSTER_RPC_PORT and CLUSTER_LAN_PORT
are used directly to compose shell commands via popen without
validation or sanitization. This behavior could allow a malicious user
to inject malicious commands through these variables within the enforcer
container.
CVSS v3.1 Base Metrics — Score 9.9 (CRITICAL)
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:HAttack VectorNetwork
Attack ComplexityLow
Privileges RequiredLow
User InteractionNone
ScopeChanged
ConfidentialityHigh
IntegrityHigh
AvailabilityHigh
Affected & Patched Versions
Not provided by NVD for this CVE.
No patched version published yet
Until a fix ships, reduce exposure:
- Restrict access to the affected service or interface to trusted networks.
- Disable the affected feature if you do not need it.
- Watch the vendor advisory for a firmware or software update.
What to do
Plan remediation soon. No exploitation is confirmed yet, but the severity is critical.
- Check whether you run the affected product and which version.
- No patched version is listed yet. Limit access to the affected service to trusted networks, and disable the feature if you can.
- Subscribe to the vendor advisory so you learn when a fix ships.
Timeline
- Oct 30, 2025Published
- Oct 30, 2025Record last modified
Score, severity and exploitation changes are tracked from the day Watchtower started logging them.
Get alerts for CVEs like this oneYou are reading CVE-2025-54469. Get an email when KEV listings, exploits or new CVEs match your stack.