CVE-2026-118450CompuGroup Medical Venere
NVD
Vulnerability Summary
Venere is installed outside Program Files and loads/registers unsigned components from locations where an unprivileged user may create files.
CVSS v4.0 Base Metrics — Score 5.9 (MEDIUM)
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:UAttack VectorLocal
Attack ComplexityLow
Attack RequirementsNone
Privileges RequiredLow
User InteractionNone
Confidentiality (Vulnerable System)High
Integrity (Vulnerable System)High
Availability (Vulnerable System)High
Confidentiality (Subsequent System)None
Integrity (Subsequent System)None
Availability (Subsequent System)None
Affected & Patched Versions
- CompuGroup Medical Venere 8.33.2
No patched version published yet
Until a fix ships, reduce exposure:
- Restrict access to the affected service or interface to trusted networks.
- Disable the affected feature if you do not need it.
- Watch the vendor advisory for a firmware or software update.
What to do
Fix it during your normal patch cycle. No exploitation is confirmed yet.
- Check whether you run CompuGroup Medical Venere and which version.
- No patched version is listed yet. Limit access to the affected service to trusted networks, and disable the feature if you can.
- Subscribe to the vendor advisory so you learn when a fix ships.
Timeline
- Nov 9, 2026Published
- Nov 12, 2026Record last modified
Score, severity and exploitation changes are tracked from the day Watchtower started logging them.
Get notified about new CompuGroup Medical Venere CVEsYou are reading CVE-2026-118450. Get an email when KEV listings, exploits or new CVEs match your stack.
Set up CVE alertsExternal References
Data last checked: Nov 15, 2026 01:08 UTC