CVE-2026-133661flowintel Missing Authorization
NVD
Vulnerability Summary
FlowIntel contains multiple authorization and credential management vulnerabilities affecting connector instances, MISP helper tools, and case templates.
- Connector instance metadata, connectivity checks, and case listings accepted instance IDs without verifying if the acting user had visibility or ownership rights, allowing unauthorized access to sensitive configuration and data.
- Case template serialization and creation processes exposed connector instances attached to templates regardless of the user's permissions, potentially leaking credentials or instance details to users who should not have access.
- Editing connector instances allowed changes to URLs or sharing scopes without requiring re-authentication of API keys, enabling the reuse of another user's credentials in a new context or the leakage of shared keys to unauthorized endpoints.
- Outbound MISP connector keys were incorrectly accepted for authenticating incoming alerts, bypassing the intended separation between outbound integration credentials and inbound alert source authentication.
These issues allow authenticated users to access unauthorized connector data, manipulate credential scopes, and potentially exploit credential confusion between different security contexts.
Affected versions: < 4.1.0
- Connector instance metadata, connectivity checks, and case listings accepted instance IDs without verifying if the acting user had visibility or ownership rights, allowing unauthorized access to sensitive configuration and data.
- Case template serialization and creation processes exposed connector instances attached to templates regardless of the user's permissions, potentially leaking credentials or instance details to users who should not have access.
- Editing connector instances allowed changes to URLs or sharing scopes without requiring re-authentication of API keys, enabling the reuse of another user's credentials in a new context or the leakage of shared keys to unauthorized endpoints.
- Outbound MISP connector keys were incorrectly accepted for authenticating incoming alerts, bypassing the intended separation between outbound integration credentials and inbound alert source authentication.
These issues allow authenticated users to access unauthorized connector data, manipulate credential scopes, and potentially exploit credential confusion between different security contexts.
Affected versions: < 4.1.0
CVSS v4.0 Base Metrics — Score 5.3 (MEDIUM)
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:NAttack VectorNetwork
Attack ComplexityLow
Attack RequirementsNone
Privileges RequiredLow
User InteractionNone
Confidentiality (Vulnerable System)Low
Integrity (Vulnerable System)Low
Availability (Vulnerable System)Low
Confidentiality (Subsequent System)None
Integrity (Subsequent System)None
Availability (Subsequent System)None
Affected & Patched Versions
- flowintel < 4.1.0
- flowintel 4.1.0
What to do
Fix it during your normal patch cycle. No exploitation is confirmed yet.
- Check whether you run flowintel and which version.
- Update to a patched version listed above, then confirm the new version.
Timeline
- Nov 20, 2026Published
- Nov 20, 2026Record last modified
Score, severity and exploitation changes are tracked from the day Watchtower started logging them.
Get notified about new flowintel CVEsYou are reading CVE-2026-133661. Get an email when KEV listings, exploits or new CVEs match your stack.
Set up CVE alertsMore flowintel CVEs
External References
Data last checked: Nov 20, 2026 11:13 UTC