CVE Watchtower

CVE-2026-136552Tenda RX3 Command Injection

NVD

Vulnerability Summary

A security vulnerability has been detected in Tenda RX3 16.03.13.11_multi. This impacts the function formSetIPv6status of the file /goform/setIPv6Status of the component multiWAN. Such manipulation of the argument remoteIP leads to command injection. The attack may be performed from remote. The exploit has been disclosed publicly and may be used.
Severity Level
CRITICAL(9.4)
Published Date
Nov 25, 2026
Last Modified
Nov 25, 2026
Exploitation Status
Public exploit available
Root Weakness (CWE)
The product constructs all or part of a command using externally-influenced input but does not neutralize special elements that could modify the intended command.
The product constructs all or part of a command, data structure, or record using externally-influenced input, but it does not neutralize or incorrectly neutralizes special elements that could modify how it is parsed or interpreted when it is sent to a downstream component.
CVSS v4.0 Base Metrics — Score 9.4 (CRITICAL)
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P
Attack VectorNetwork
Attack ComplexityLow
Attack RequirementsNone
Privileges RequiredHigh
User InteractionNone
Confidentiality (Vulnerable System)High
Integrity (Vulnerable System)High
Availability (Vulnerable System)High
Confidentiality (Subsequent System)High
Integrity (Subsequent System)High
Availability (Subsequent System)High
Show CVSS v3.x metrics (score 9.1)
CVSS v3.1 Base Metrics — Score 9.1 (CRITICAL)
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R
Attack VectorNetwork
Attack ComplexityLow
Privileges RequiredHigh
User InteractionNone
ScopeChanged
ConfidentialityHigh
IntegrityHigh
AvailabilityHigh

Affected & Patched Versions

Affected Versions
  • Tenda RX3 16.03.13.11_multi
Patched Versions
No patched version published yet
Until a fix ships, reduce exposure:
  • Restrict access to the affected service or interface to trusted networks.
  • Disable the affected feature if you do not need it.
  • Watch the vendor advisory for a firmware or software update.

What to do

Prioritize this fix. Exploit code is public, so attacks can follow quickly.

  1. Check whether you run Tenda RX3 and which version.
  2. No patched version is listed yet. Limit access to the affected service to trusted networks, and disable the feature if you can.
  3. Subscribe to the vendor advisory so you learn when a fix ships.
  4. Review logs and exposed services for signs of earlier compromise.

Timeline

  • Nov 25, 2026Published
  • Nov 25, 2026Record last modified

Score, severity and exploitation changes are tracked from the day Watchtower started logging them.

Get notified about new Tenda RX3 CVEsYou are reading CVE-2026-136552. Get an email when KEV listings, exploits or new CVEs match your stack.
Set up CVE alerts

Data last checked: Nov 25, 2026 06:28 UTC