← Back to CVE List
CVE-2026-19003NVD
Vulnerability Summary
A data source definition containing an over-length file path setting may cause the MongoDB BI Connector ODBC Driver setup dialog to write outside the bounds of an allocated buffer. The issue stems from an incorrect buffer capacity calculation in the dialog's file and folder selection handling, and is reached only when a user opens the setup dialog for such a data source and initiates a file or folder selection. Depending on build configuration, the result may range from abnormal process termination to, under certain conditions, execution of unintended code in the context of the user running the dialog.
CVSS v4.0 Base Metrics — Score 8.4 (HIGH)
Attack VectorLocal
Attack ComplexityLow
Attack RequirementsNone
Privileges RequiredNone
User InteractionActive
Confidentiality (Vulnerable System)High
Integrity (Vulnerable System)High
Availability (Vulnerable System)High
Confidentiality (Subsequent System)None
Integrity (Subsequent System)None
Availability (Subsequent System)None
CVSS v3.1 Base Metrics — Score 7.8 (HIGH)
Attack VectorLocal
Attack ComplexityLow
Privileges RequiredNone
User InteractionRequired
ScopeUnchanged
ConfidentialityHigh
IntegrityHigh
AvailabilityHigh
Affected & Patched Versions
- MongoDB BI Connector ODBC Driver >= 1.0.0 and < 1.4.9
- MongoDB BI Connector ODBC Driver 1.4.9