CVE-2026-31255Tenda Ac18 Firmware Command Injection
NVDCVSS scored by NVD (NIST)
Vulnerability Summary
A command injection vulnerability exists in Tenda AC18 V15.03.05.05_multi. The vulnerability is located in the /goform/SetSambaCfg interface, where improper handling of the guestuser parameter allows attackers to execute arbitrary system commands.
CVSS v3.1 Base Metrics — Score 9.8 (CRITICAL)
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HAttack VectorNetwork
Attack ComplexityLow
Privileges RequiredNone
User InteractionNone
ScopeUnchanged
ConfidentialityHigh
IntegrityHigh
AvailabilityHigh
Affected & Patched Versions
- Tenda Ac18 Firmware
No patched version published yet
Until a fix ships, reduce exposure:
- Restrict access to the affected service or interface to trusted networks.
- Disable the affected feature if you do not need it.
- Watch the vendor advisory for a firmware or software update.
What to do
Prioritize this fix. Exploit code is public, so attacks can follow quickly.
- Check whether you run Tenda Ac18 Firmware and which version.
- No patched version is listed yet. Limit access to the affected service to trusted networks, and disable the feature if you can.
- Subscribe to the vendor advisory so you learn when a fix ships.
- Review logs and exposed services for signs of earlier compromise.
Timeline
- Apr 27, 2026Published
- Nov 11, 2026Record last modified
Score, severity and exploitation changes are tracked from the day Watchtower started logging them.