CVE Watchtower

CVE-2026-80154

NVD

Vulnerability Summary

All firmware versions of Lantronix SLC8000, SLC9000, EMG8500, EMG7500, SLB882, SLCx-03, and SLCx-02 contain an authentication bypass vulnerability in the web management portal that allows unauthenticated attackers to derive valid session tokens of logged-in users and bypass source IP and User-Agent validation. Session tokens are generated deterministically from the device model and the current time at one-second resolution, resulting in a small enumerable set of possible active tokens. Attackers can construct a crafted URI that exploits file extension handling in the web server path routing to bypass per-session source-address validation, then use a derived token from a different source address to gain elevated privileges on the affected device and potentially impact downstream serial-attached devices.
Severity Level
HIGH(8.9)
Published Date
Sep 22, 2026
Last Modified
Nov 17, 2026
Exploitation Status
No confirmed exploitation yet
EPSS Score (30-Day)
0.63%Probability
Root Weakness (CWE)
See the MITRE CWE entry for the full definition of this weakness.
CVSS v4.0 Base Metrics — Score 8.9 (HIGH)
CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
Attack VectorNetwork
Attack ComplexityLow
Attack RequirementsPresent
Privileges RequiredNone
User InteractionActive
Confidentiality (Vulnerable System)High
Integrity (Vulnerable System)High
Availability (Vulnerable System)High
Confidentiality (Subsequent System)High
Integrity (Subsequent System)High
Availability (Subsequent System)High
Show CVSS v3.x metrics (score 9.6)
CVSS v3.1 Base Metrics — Score 9.6 (CRITICAL)
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H
Attack VectorNetwork
Attack ComplexityLow
Privileges RequiredNone
User InteractionRequired
ScopeChanged
ConfidentialityHigh
IntegrityHigh
AvailabilityHigh

Affected & Patched Versions

Affected Versions
Not provided by NVD for this CVE.
Patched Versions
No patched version published yet
Until a fix ships, reduce exposure:
  • Restrict access to the affected service or interface to trusted networks.
  • Disable the affected feature if you do not need it.
  • Watch the vendor advisory for a firmware or software update.

What to do

Plan remediation soon. No exploitation is confirmed yet, but the severity is high.

  1. Check whether you run the affected product and which version.
  2. No patched version is listed yet. Limit access to the affected service to trusted networks, and disable the feature if you can.
  3. Subscribe to the vendor advisory so you learn when a fix ships.

Timeline

  • Sep 22, 2026Published
  • Nov 17, 2026Record last modified

Score, severity and exploitation changes are tracked from the day Watchtower started logging them.

Get alerts for CVEs like this oneYou are reading CVE-2026-80154. Get an email when KEV listings, exploits or new CVEs match your stack.
Set up CVE alerts

Data last checked: Nov 17, 2026 23:14 UTC