CVE-2026-52723NVD

Vulnerability Summary

ePA 3.x Integration implements the authorization workflow and writes Medical Information Objects to Germany's electronic patient record. Prior to 1.3.0, ePA 3.x Integration performs VAU server certificate validation in app/vau/VAUProtokoll.py without anchoring the signed_vau_server_pub_keys and AUT_VAU_CertData certificate path to independent trusted material. A network-positioned attacker between the DiGA backend and the ePA system can intercept the VAU handshake, supply attacker-controlled certificate and key material, and satisfy the circular trust relationship. Because TLS certificate verification is also disabled in affected versions, no independent server-authentication layer prevents the attack. The attacker can impersonate the VAU server, control the negotiated session keys, and read or modify all encrypted VAU traffic. This issue is fixed in version 1.3.0.
Severity Level
CRITICAL(9.1)
Published Date
Aug 18, 2026
Last Modified
Aug 18, 2026
Exploitation Status
No confirmed exploitation yet
EPSS Score (30-Day)
Data Pending
Root Weakness (CWE)
Refer to the official MITRE database for detailed architectural specifications regarding this weakness.
CVSS v3.1 Base Metrics
Attack VectorNetwork
Attack ComplexityLow
Privileges RequiredNone
User InteractionNone
ScopeUnchanged
ConfidentialityHigh
IntegrityHigh
AvailabilityNone