CVE-2024-12297
NVDCVSS scored by psirt@moxa.com
Vulnerability Summary
Moxa’s Ethernet switch is vulnerable to an authentication bypass because of flaws in its authorization mechanism. Although both client-side and back-end server verification are involved in the process, attackers can exploit weaknesses in its implementation. These vulnerabilities may enable brute-force attacks to guess valid credentials or MD5 collision attacks to forge authentication hashes, potentially compromising the security of the device.
CVSS v4.0 Base Metrics — Score 9.2 (CRITICAL)
CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XAttack VectorNetwork
Attack ComplexityLow
Attack RequirementsPresent
Privileges RequiredNone
User InteractionNone
Confidentiality (Vulnerable System)High
Integrity (Vulnerable System)High
Availability (Vulnerable System)High
Confidentiality (Subsequent System)Low
Integrity (Subsequent System)Low
Availability (Subsequent System)Low
Affected & Patched Versions
Not provided by NVD for this CVE.
No patched version published yet
Until a fix ships, reduce exposure:
- Restrict access to the affected service or interface to trusted networks.
- Disable the affected feature if you do not need it.
- Watch the vendor advisory for a firmware or software update.
What to do
Plan remediation soon. No exploitation is confirmed yet, but the severity is critical.
- Check whether you run the affected product and which version.
- No patched version is listed yet. Limit access to the affected service to trusted networks, and disable the feature if you can.
- Subscribe to the vendor advisory so you learn when a fix ships.
Timeline
- Jan 15, 2025Published
- Mar 6, 2025Record last modified
Score, severity and exploitation changes are tracked from the day Watchtower started logging them.
Get alerts for CVEs like this oneYou are reading CVE-2024-12297. Get an email when KEV listings, exploits or new CVEs match your stack.
Set up CVE alertsRelated Coverage
- CVE-2024-12297 (CVSS 9.2): Critical Authorization Vulnerability in Moxa EDS-508A Series
- Industrial Alert: Critical Auth Bypass (CVSS 9.2) Hits Moxa Switches
- NVIDIA’s New Ethernet Tech Turns Distributed Data Centers Into a Single AI “Superfactory”
- CVE-2025-0676: High-Severity Vulnerability Threatens Moxa Network Devices
- Critical Vulnerability in Moxa PT Switches Allows Unauthorized Access
External References
- Vendor Advisoryhttps://www.moxa.com/en/support/product-support/security-advisory/mpsa-241407-cve-2024-12297-frontend-authorization-logic-disclosure-vulnerability-in-eds-508a-series
- Vendor Advisoryhttps://www.moxa.com/en/support/product-support/security-advisory/mpsa-241408-cve-2024-12297-frontend-authorization-logic-disclosure-vulnerability-identified-in-pt-switches
Data last checked: Nov 22, 2026 16:06 UTC