CVE-2026-133001flowintel Exposure of Resource to Wrong Sphere

NVD

Vulnerability Summary

FlowIntel contains an authorization flaw in its duplicate alert ingestion logic. When a duplicate alert is received and its content is updated, the ownership and visibility scope fields (owner user and owner organization) were not refreshed to reflect the connector's current scope. As a result, an alert that was originally created under a broader visibility scope retained that broader scope even after the connector's scope was narrowed or changed.

This means that users or organizations that should no longer have visibility into a given alert could continue to access it, because the stale ownership fields were never updated during the duplicate-update path. The issue affected all duplicate updates, including those involving alerts in terminal review states and those recovered from uniqueness conflicts.

Security impact:
- Unauthorized disclosure of security alert content to users or organizations outside the intended visibility scope.
- Stale access persists indefinitely until the alert is independently re-scoped or deleted.

Affected version: <4.1.0.
Severity Level
MEDIUM(5.3)
Published Date
Nov 19, 2026
Last Modified
Nov 19, 2026
Exploitation Status
No confirmed exploitation yet
EPSS Score (30-Day)
0.31%Probability
Root Weakness (CWE)
The product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource.
The software does not perform an authorization check when an actor attempts to access a resource or perform an action.
CVSS v4.0 Base Metrics — Score 5.3 (MEDIUM)
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N
Attack VectorNetwork
Attack ComplexityLow
Attack RequirementsNone
Privileges RequiredLow
User InteractionNone
Confidentiality (Vulnerable System)Low
Integrity (Vulnerable System)None
Availability (Vulnerable System)None
Confidentiality (Subsequent System)None
Integrity (Subsequent System)None
Availability (Subsequent System)None

Affected & Patched Versions

Affected Versions
  • flowintel <= 4.0.0
Patched Versions
  • flowintel 4.0.0

What to do

Fix it during your normal patch cycle. No exploitation is confirmed yet.

  1. Check whether you run flowintel and which version.
  2. Update to a patched version listed above, then confirm the new version.

Timeline

  • Nov 19, 2026Published
  • Nov 19, 2026Record last modified

Score, severity and exploitation changes are tracked from the day Watchtower started logging them.